Taking advantage of the 1F upgrade path for those connecting via the Modbus connection... Well, you're in the right place to find out what you need.
The bottom block is V4
VFD Upgrade, Spindle Cable & GX12-6 Pin to GX12-6 Pin
|
VFD Enclosure Upgrade & GX12-6 Pin to GX12-6 Pin
|
GX12-6 Pin to GX12-6 Pin connector cable and make the following changes in your VFD: P0.0.03 = 1 P0.0.04 = 3 |
DIY VFD Upgrade is not available.
We cannot tell you if you have V3 or V4 based on your order date as we would only be guessing based on memory.
V5's started shipping 1 November 2023, if you have a V5 the solution is the same as a V4, control cable and the above listed programming changes.
You'll know you have a V5 with black aluminum top, bottom, front, back panels and a "Run" port on the left.
Contact us at [email protected] if you have questions.